User Tools

Site Tools


analysis:amplipex:artifacts

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
analysis:amplipex:artifacts [2014/01/20 16:19]
ecarmichael [Visual Artifact Removal]
analysis:amplipex:artifacts [2018/07/07 10:19] (current)
Line 28: Line 28:
 {{:​analysis:​amplipex:​artifact_wiki.png?​750|}} {{:​analysis:​amplipex:​artifact_wiki.png?​750|}}
  
-The selected artifact regions are not altered within the data itself, instead the start and end of each artifact are saved as part of the cfg structure: data_trl.cfg.artfctdef.visual.artifact . From here we can change these regions to values ​of our choice.  ​+The selected artifact regions are not altered within the data itself, instead the start and end of each artifact are saved as part of the cfg structure: data_trl.cfg.artfctdef.visual.artifact . So now can change these regions to any value of our choice.  ​
  
  
Line 42: Line 42:
                 data_trl.trial{1,​iTrial}(1:​16,​(1:​artifacts(iArt,​2)-trials(iTrial,​1)))=art_value;​                 data_trl.trial{1,​iTrial}(1:​16,​(1:​artifacts(iArt,​2)-trials(iTrial,​1)))=art_value;​
             else             else
-            ​data_rl.trial{1,​iTrial}(1:​16,​(artifacts(iArt,​1)-trials(iTrial,​1):​artifacts(iArt,​2)-trials(iTrial,​1)))=art_value;​+            ​data_trl.trial{1,​iTrial}(1:​16,​(artifacts(iArt,​1)-trials(iTrial,​1):​artifacts(iArt,​2)-trials(iTrial,​1)))=art_value;​
             end             end
         end         end
Line 50: Line 50:
  
  
-From here we can visualize the data regions that have been replaced to ensure they have been correctly converted. ​+Now we can visualize the data regions that have been replaced to ensure they have been correctly converted. ​
  
 <code matlab> <code matlab>
 cfg.viewmode ​   = '​vertical';​ % this shows all of the channels vertically cfg.viewmode ​   = '​vertical';​ % this shows all of the channels vertically
-ft_databrowser(cfg,​data_trl_og);+ft_databrowser(cfg,​data_trl);
 </​code>​ </​code>​
  
 From here we can run any further ft analysis.  ​ From here we can run any further ft analysis.  ​
analysis/amplipex/artifacts.1390252799.txt.gz ยท Last modified: 2018/07/07 10:19 (external edit)